Zeta Fire Alarm Control Panel Manual - Download Free Apps
Posted By admin On 30/05/18• Fire Alarm System + Fire Alarm System. An automatic fire alarm system is designed to detect the unwanted presence of fire by monitoring environmental • Fire Alarm Testing Equipments + Fire detector test and service equipment must be safe both for engineer and system. As a minimum it must comply • Emergency Lights + Self Contained Emergency Lights Monitoring Type • CC TV Security and Access Control System + • Fire Hose Reel System + Fire hose reels are a basic requirement for fire protection.
Soulknife Handbook D&d. This will help you to suppress fire before it spread.
Bitlord 1.1 For Mac. • INFINITY 8 INSTALLATION MANUAL FIRE ALARM CONTROL PANEL INSTALLATION MANUAL Approved Document No. GLT-201-7-1 Issue: 1.6 Author: NRPJ Date: 27/7/2012. • INFINITY 8 INSTALLATION MANUAL CONTENTS 1.
1.1 HANDLING THE PCBS....1.2 USING THIS MANUAL....1.3 ABOUT THE INFINITY FIRE ALARM CONTROL PANEL & INTEGRAL PSE.. 1.4 DESIGNING THE SYSTEM.... 1.5 EQUIPMENT GUARANTEE....1.6 DEFINITION OF ACCESS LEVELS ON THE INFINITY PANEL... • 1.2 USING THIS MANUAL This manual explains, in a step-by-step manner, the procedure for the installation of the Infinity 8 Range of Fire Alarm Control Panels. For full operational and maintenance information, please refer to document GLT.MAN- (USER MANUAL, MAINTENANCE GUIDE &. • INFINITY 8 INSTALLATION MANUAL 1.6 DEFINITION OF ACCESS LEVELS ON THE INFINITY PANEL ACCESS LEVEL ACCESSED BY ACCESS METHOD FUNCTIONS ACCESSED General public Default state View panel Override delay (if used) LED test Responsible person Access code entered Start/stop sounders.
MKII Soft & Hard Addressable Fire Alarm System. Simplicity Plus Analogue Addressable Fire Alarm Panels. New 'Zeta Remote' iPhone App for the SmartConnect Panel.
• INFINITY 8 INSTALLATION MANUAL 2. FIRST FIX All wiring must be installed to meet BS5839: Pt1: 2002 and BS 7671 (Wiring Regs) standards.
Other National standards of fire alarm system installation should be adhered to where applicable. 2.1 RECOMMENDED CABLE TYPES AND THEIR LIMITATIONS Screened cables should be used throughout the installation to help shield the Panel from outside interference and ensure EMC compatibility. • INFINITY 8 INSTALLATION MANUAL page).
Other makes of detector will have different connections, but in general they are wired +IN & +OUT to same terminal, -IN to stripe side of continuity diode, -OUT to non-stripe side of continuity diode. Some makes will connect the +ve to a 470R load resistor, or a polarisation diode, to enable the detector to work correctly.
• INFINITY 8 INSTALLATION MANUAL The termination for the above inputs must be as indicated on the main PCB (See page 15). The Earthing of the cable screens should be as shown on page 9. PAGE 6 Approved Document No. GLT-201-7-1 Issue: 1.6. • INFINITY 8 INSTALLATION MANUAL 3.
MOUNTING THE FIRE ALARM PANEL It is recommended that the panel’s door be removed to avoid accidental damage. Also, the termination PCB could be removed and stored in a safe place, while fixing the back box to the wall. • INFINITY 8 INSTALLATION MANUAL 4.
Klapa Crikvenica Vilo Moja Mp3. CONNECTING MAINS & BATTERY POWER 4.1 CONNECTING THE MAINS POWER Figure 3: Power Supply PCB layout and Mains connection details Figure 3 4.2 CONNECTING THE BATTERIES Figure 4: Battery location and connection details CAUTION: RISK OF EXPLOSION IF BATTERY IS REPLACED BY AN INCORRECT TYPE. • INFINITY 8 INSTALLATION MANUAL 5. FIELD DEVICE TERMINATION 5.1 TERMINATING THE DETECTION AND ALARM (SOUNDER) CIRCUITS All cables entering the enclosure should use cable glands.
The Detector and Sounder circuits should be connected to the appropriate connector block on the Termination PCB as shown in Figure 6 below. All screens should be fed through the gland to make electrical contact with it, and be terminated at the brass earthing strip as shown below (see Figure 6) (For detailed detector and alarm circuit wiring diagrams, please refer to pages 6 and 7.) • INFINITY 8 INSTALLATION MANUAL 6. SOUNDER ACTIVATION DELAY 6.1 DECIDING TO USE A DELAY A delay of up to ten minutes from the Fire Alarm Panel being triggered, to its Alarm sounder outputs being activated, can be programmed into the panel by the Engineer. This is a particularly useful feature for schools, nightclubs and other public places where the nuisance and panic caused by a false alarm must be avoided.